Datasheet
Electrical characteristics STM32F100xC, STM32F100xD, STM32F100xE
38/98 Doc ID 15081 Rev 7
Note: It is recommended to power V
DD
and V
DDA
from the same source. A maximum difference of
300 mV between V
DD
and V
DDA
can be tolerated during power-up and operation
5.3.2 Operating conditions at power-up / power-down
Subject to general operating conditions for T
A
.
Table 10. Operating conditions at power-up / power-down
P
D
Power dissipation at T
A
=
85 °C for suffix 6 or T
A
=
105 °C for suffix 7
(2)
LQFP144 666
mWLQFP100 434
LQFP64 444
TA
Ambient temperature for 6
suffix version
Maximum power dissipation –40 85
°C
Low power dissipation
(3)
–40 105
Ambient temperature for 7
suffix version
Maximum power dissipation –40 105
°C
Low power dissipation
(3)
–40 125
T
J Junction temperature range
6 suffix version –40 105
°C
7 suffix version –40 125
1. When the ADC is used, refer to Table 51: ADC characteristics.
2. If T
A
is lower, higher P
D
values are allowed as long as T
J
does not exceed T
J
max (see Section 6.2:
Thermal characteristics on page 92).
3. In low power dissipation state, T
A
can be extended to this range as long as T
J
does not exceed T
J
max (see
Section 6.2: Thermal characteristics on page 92).
Table 9. General operating conditions (continued)
Symbol Parameter Conditions Min Max Unit
Symbol Parameter Min Max Unit
t
VDD
V
DD
rise time rate 0
∞
µs/V
V
DD
fall time rate 20
∞