Datasheet
Testing the board AN4164
12/38 Doc ID 023660 Rev 1
5 Testing the board
5.1 Typical waveforms
Drain voltage and current waveforms in full load condition are shown for the two nominal
input voltages in
Figure 9
and
10
, and for minimum and maximum input voltage in
Figure 11
and
12
respectively.
Figure 9. Drain current/voltage at 115 V
ac
,
max. load
Figure 10. Drain current/voltage at 230 V
ac
,
max. load
AM13335v1
AM13336v1
Figure 11. Drain current/voltage at 90 V
ac
,
max. load
Figure 12. Drain current/voltage at 265 V
ac
,
max. load
AM13337v1
AM13338v1