13 EMI measurements
A pre-compliance test to EN55022 (Class B) European normative has been performed
using an EMC analyzer and an LISN. First of all, a measurement of the background noise
(board disconnected from the mains) was performed and is shown in
Figure 39
.
Then the peak and average EMC measurements at 115 V
AC
/full load and 230 V
AC
/full load
were performed and the results are shown in
Figure 40
,
41
,
42
and
43
.
Figure 39. Background noise measurement
Figure 40. Peak measurement at 115 V
AC
/full load
AM13386v1
AM13387v1