Datasheet
Typical application STEF12
8/20 Doc ID 019056 Rev 5
5 Typical application
Figure 3. Application circuit
Figure 4. Typical HDD application circuit
5.1 Operating modes
5.1.1 Turn-on
When the input voltage is applied, the Enable/Fault pin goes up to the high state, enabling
the internal control circuitry.
After an initial delay time of typically 350 ยตs, the output voltage is supplied with a slope
defined by the internal dv/dt circuitry. If no additional capacitor is connected to dv/dt pin, the
total time from the Enable signal going high and the output voltage reaching the nominal
value is around 1 ms (refer to
Figure 5, 15
)
AM09869v1