Datasheet

STBP120 Timing diagrams
Doc ID 15492 Rev 5 17/36
7 Timing diagrams
Figure 6. Startup
(1)
1. EN
input is low.
Figure 7. Overvoltage protection
(1)
1. EN
input is low.
AM00335
t
start
OVLO
UVLO
V
IN
V
OUT
V
(FLT)
t
on
0.3 V
1.2 V
AM00336
t
stop
OVLO
UVLO
V
IN
V
OUT
V
(FLT)
t
off
0.3 V
0.4 V