Datasheet
Absolute maximum ratings STBB1-AXX
4/22 Doc ID 022197 Rev 2
2 Absolute maximum ratings
Note: Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these conditions is not implied.
Table 2. Absolute maximum ratings
Symbol Parameter Value Unit
VINA, VIN Input voltage - 0.3 to 7 V
VOUT Output voltage - 0.3 to 7 V
SW1, SW2 DC voltage - 0.3 to 7 V
FB DC voltage - 0.3 to 1.5 V
MOD/SYNC, EN DC voltage - 0.3 to 7 V
T
J
Maximum junction temperature 150 °C
T
STG
Storage temperature range - 65 to + 150 °C
T
JOP
Operating junction temperature range - 40 to + 85 °C
ESD Human body model 2 kV
Table 3. Thermal data
Symbol Parameter Value Unit
R
thJC
Thermal resistance junction-case 2.96 °C/W
R
thJA
Thermal resistance junction-ambient 30.9 °C/W