Datasheet

Functional description ST1S41
14/27 DocID023654 Rev 2
The current foldback is disabled during the startup to allow the Vout to start up properly in
case of a big output capacitor requiring high extra current to be charged.
A further mechanism is protecting the device in case of short-circuit on the output and high
input voltage. A further threshold (OCP2, 1 A higher than OCP1) is compared to the inductor
current. If the inductor current exceeds OCP2, the device stops switching and it restarts with
a soft-start cycle.
5.4 Enable function
The enable feature allows the device to be put into standby mode. With the EN pin lower
than 0.4 V, the device is disabled and the power consumption is reduced to less than 15 uA.
With the EN pin higher than 1.2 V, the device is enabled. If the EN pin is left floating, an
internal pull-down ensures that the voltage at the pin reaches the inhibit threshold and the
device is disabled. The pin is also V
IN
compatible.
5.5 Hysteretic thermal shutdown
The thermal shutdown block generates a signal that turns off the power stage if the junction
temperature goes above 150 °C. Once the junction temperature goes back to about 130 °C,
the device restarts in normal operation.