Datasheet
SMP100MC Application information
Doc ID 9699 Rev 5 7/13
Figure 11. Typical circuits
Figure 12. Test method of the board having fuse and Trisil
These topologies, using SMP100MC from ST and TCP1.25 A from Cooper Bussmann, have
been functionally validated with a Trisil glued on the PCB. Following example was performed
with SMP100MC-270 Trisil. For more information, see Application Note AN2064.
Figure 13. Trisil turns on during lightning surge
Test conditions:
2/10 µs + and -2.5 and 5 kV 500 A (10 pulses of each polarity), T
amb
= 25 °C
Test result:
Fuse and Trisil OK after test in accordance with GR1089 requirements.
Fuse TCP 1.25A
T1
T2
SMP100MC-xxx
Fuse TCP 1.25A
Tip S
Gnd
SMP100MC-xxx
Ring S
SMP100MC-xxx
Fuse TCP 1.25A
Tip L
Gnd
Ring L
Typical circuit for subscriber side Typical circuit for central office side
Surge
Generator
Device to be protected
V
Oscilloscope
I surge
Line side
Voltage probe
Current probe
Test board