Datasheet
SM6TY Characteristics
Doc ID 17741 Rev 3 3/12
Table 2. Electrical characteristics, parameter values (T
amb
= 25 °C)
Order code
I
RM
max @ V
RM
V
BR
@I
R
(1)
V
CL
@ I
PP
10/1000 µs
R
D
(2)
10/1000 µs
V
CL
@ I
PP
8/20 µs
R
D
(2)
8/20 µs
αT
25 °C 85 °C min. typ. max. max. max. max.
µA V V mA V
(3)
A
(4)
Ω V
(3)
A
(4)
Ω 10-4/ °C
SM6T6V8AY/CAY 20 50 5.80 6.45 6.80 7.10 10 10.5 57.0 0.059 13.4 298 0.021 5.70
SM6T7V5AY/CAY 20 50 6.40 7.13 7.50 7.90 10 11.3 53.0 0.065 14.5 276 0.024 6.10
SM6T10AY/CAY 20 50 8.55 9.50 10.0 10.5 1 14.5 41.0 0.098 18.6 215 0.038 7.30
SM6T12AY/CAY 0.2 1 10.2 11.4 12.0 12.6 1 16.7 36.0 0.114 21.7 184 0.049 7.80
SM6T15AY/CAY 0.2 1 12.8 14.3 15.0 15.8 1 21.2 28v 0.193 27.2 147 0.078 8.40
SM6T18AY/CAY 0.2 1 15.3 17.1 18.0 18.9 1 25.2 24.0 0.263 32.5 123 0.111 8.80
SM6T22AY/CAY 0.2 1 18.8 20.9 22.0 23.1 1 30.6 20.0 0.375 39.3 102 0.159 9.20
SM6T24AY/CAY 0.2 1 20.5 22.8 24.0 25.2 1 33.2 18.0 0.444 42.8 93.0 0.189 9.40
SM6T27AY/CAY 0.2 1 23.1 25.7 27.0 28.4 1 37.5 16.0 0.569 48.3 83.0 0.240 9.60
SM6T30AY/CAY 0.2 1 25.6 28.5 30.0 31.5 1 41.5 14.5 0.69 53.5 75.0 0.293 9.70
SM6T33AY/CAY 0.2 1 28.2 31.4 33.0 34.7 1 45.7 13.1 0.84 59.0 68.0 0.357 9.80
SM6T36AY/CAY 0.2 1 30.8 34.2 36.0 37.8 1 49.9 12.0 1.01 64.3 62.0 0.427 9.90
SM6T39AY/CAY 0.2 1 33.3 37.1 39.0 41.0 1 53.9 11.1 1.16 69.7 57.0 0.504 10.0
SM6T42AY/CAY 0.2 1 36.0 40.0 42.1 44.2 1 58.1 10.3 1.35 76.0 52.0 0.611 10.0
SM6T47AY/CAY 0.2 1 40.0 44.4 46.7 49.0 1 64.5 9.7 1.59 84.0 48.0 0.728 10.1
SM6T56AY/CAY 0.2 1 47.6 53.2 56.0 58.8 1 76.6 7.8 2.28 100 40.0 1.03 10.0
SM6T68AY/CAY 0.2 1 58.1 64.6 68.0 71.4 1 92 6.5 3.17 121 33.0 1.50 10.4
SM6T75AY/CAY 0.2 1 64.1 71.3 75.0 78.8 1 103 5.8 4.17 134 30.0 1.84 10.5
SM6T82AY/CAY 0.2 1 70.0 77.8 81.9 86.0 1 113 5.5 4.91 146 27.0 2.22 10.5
1. Pulse test: t
p
< 50 ms
2. To calculate maximum clamping voltage at another surge level, use the following formula:
V
CLmax
= V
CL
- R
D
x (I
PP
- I
PPappli
) where I
PPappli
is the surge current in the application.
3. To calculate V
BR
or V
CL
versus junction temperature, use the following formulas:
V
BR
@ T
J
= V
BR
@ 25°C x (1 + αT x (T
J
- 25))
V
CL
@ T
J
= V
CL
@ 25°C x (1 + αT x (T
J
- 25))