Datasheet
Figure 10. Figure 11.
For single-ended supplies, the driver outputs are
grounded. The V
C
terminal is switched to ground by
the totem-pole source transistors on alternate oscil-
lator cycles.
In conventional push-pull bipolar designs, forward
base drive is controlled by R
1
- R
3
. Rapid turn-off
times for the power devices are achieved with
speed-up capacitors C
1
and C
2
.
The low source impedance of the output drivers pro-
vides rapid charging of Power Mos input capaci-
tance while minimizing external components.
Low power transformers can be driven directly.
Automatic reset occurs during dead time, when both
ends of the primary winding are switched to ground.
Figure 8. Figure 9
.
SG2525A-SG3525A