Device registers VL6180X
56/79 DocID026171 Rev 6
6.2.29 SYSRANGE__VHV_RECALIBRATE
Address: 0x02E
Type: R/W
Reset: 0x0
Description:
6.2.30 SYSRANGE__VHV_REPEAT_RATE
Address: 0x031
Type: R/W
Reset: 0x0
Description:
76543210
RESERVED
sysrange__vhv_status
sysrange__vhv_recalibrate
RR/WR/W
[1] sysrange__vhv_status: FW controlled status bit showing when FW has completed auto-vhv
process.
0: FW has finished autoVHV operation
1: During autoVHV operation
[0] sysrange__vhv_recalibrate: User-Controlled enable bit to force FW to carry out recalibration of
the VHV setting for sensor array. FW clears bit after operation carried out.
0: Disabled
1: Manual trigger for VHV recalibration. Can only be called when ALS and ranging are in STOP
mode
76543210
sysrange__vhv_repeate_rate
R/W
[7:0] sysrange__vhv_repeat_rate: User entered repeat rate of auto VHV task (0 = off, 255 = after
every 255 measurements)