User manual

Device registers VL6180X
46/79 DocID026171 Rev 6
6.2.9 SYSTEM__MODE_GPIO0
Address: 0x010
Type: R/W
Reset: 0x60
Description:
76543210
RESERVED
system__gpio0_is_xshutdown
system__gpio0_polarity
system__gpio0_select
RESERVED
R R/W R/W R/W R/W
[6] system__gpio0_is_xshutdown: Priority mode - when enabled, other bits of the register are
ignored. GPIO0 is main XSHUTDOWN input.
0: Disabled
1: Enabled - GPIO0 is main XSHUTDOWN input.
[5] system__gpio0_polarity: Signal Polarity Selection.
0: Active-low
1: Active-high
[4:1] system__gpio0_select: Functional configuration options.
0000: OFF (Hi-Z)
1000: GPIO Interrupt output
[0] Reserved. Write 0.