User manual

Functional description VL6180X
16/79 DocID026171 Rev 6
2.4 Operating modes
Table 5. describes the operating modes of this device.
Modes 1 and 2 are single-shot range and ALS measurements.
Modes 3 and 4 are stand-alone, continuous operation for either range or ALS.
Modes 5 and 6 are for mixed continuous and single-shot mode operations where
regular measurements are required from one of the sensors and only occasional
measurements are required from the other.
Note: In modes 5 and 6, single-shot operation takes the priority i.e. if a scheduled measurement is
in progress when the host requests a single-shot measurement, the scheduled
measurement will be aborted and will resume on the next available time slot.
Mode 7 allows both ALS and range measurements to be scheduled at regular intervals.
The ALS measurement is completed first immediately followed by a range
measurement. Interleaved mode is described in more detail in Section 2.4.3.
Table 5. Operating modes
Mode Function
Range ALS
Priority
Single Continuous Single Continuous
1 Range single-shot Range
2 ALS single-shot ALS
3 Range continuous Range
4 ALS continuous ALS
5
Range continuous and
ALS single-shot
•• ALS
6
Range single-shot and
ALS continuous
••Range
7
Interleaved mode:
Range Continuous and
ALS Continuous
-