THERMAL DATA
R
thj-case
Thermal Resistance Junction-case Max 6.0
o
C/W
ELECTRICAL CHARACTERISTICS (T
case
= 25
o
C unless otherwise specified)
Symbol Parameter Test Conditions Min. Typ. Max. Unit
I
CBO
Collector Cut-off
Current (I
E
= 0)
V
CB
= 300 V 100 µA
I
EBO
Emitter Cut-off Current
(I
C
= 0)
V
EB
= 3 V 100 µA
V
CEO(sus)
∗ Collector-Emitter
Sustaining Voltage
(I
B
= 0)
I
C
= 1 mA 300 V
h
FE
DC Current Gain I
C
= 50 mA V
CE
= 10 V 30 240
∗ Pulsed: Pulse duration = 300µs, duty cycle ≤ 2%
Safe Operating Area Derating Curve
MJE340 / MJE350