Datasheet

MC33172 MC35172 Absolute maximum ratings and operating conditions
3/9
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings (AMR)
Symbol Parameter Value Unit
V
CC
Supply voltage ±22 V
V
id
Differential input voltage see note
(1)
1. Either or both input voltages must not exceed the magnitude of V
CC
.
V
V
in
Input voltage see note 1 V
Output short-circuit duration Indefinite s
T
oper
Operating free-air temperature range
MC33172
MC35172
-40 to 105
-55 to 125
°C
R
thja
Thermal resistance junction to ambient
(2)
SO-8
DIP8
2. Short-circuits can cause excessive heating and destructive dissipation. Values are typical.
125
85
°C/W
R
thjc
Thermal resistance junction to case
(2)
SO-8
DIP8
40
41
°C/W
T
j
Junction temperature 150 °C
T
stg
Storage temperature -65 to 150 °C
ESD
HBM: human body model
(3)
3. Human body model: A 100 pF capacitor is charged to the specified voltage, then discharged through a
1.5 kΩ resistor between two pins of the device. This is done for all couples of connected pin combinations
while the other pins are floating.
2kV
MM: machine model
(4)
4. Machine model: A 200 pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of
connected pin combinations while the other pins are floating.
200 V
CDM: charged device model
(5)
5. Charged device model: all pins and the package are charged together to the specified voltage and then
discharged directly to the ground through only one pin. This is done for all pins.
1kV
Latch-up immunity Class A
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage ±2 to ±22 V