Datasheet

23/42
M95640, M95320
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 10. Operating Conditions (M95320 and M95640)
Table 11. Operating Conditions (M95320-W and M95640-W)
Table 12. Operating Conditions (M95320-R and M95640-R)
Note: 1. This product is under development. For more information, please contact your nearest ST sales office.
Table 13. Operating Conditions (M95320-S and M95640-S)
Note: 1. This product is under development. For more information, please contact your nearest ST sales office.
Table 14. AC Measurement Conditions
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 4.5 5.5 V
T
A
Ambient Operating Temperature (Device Grade 6) –40 85 °C
Ambient Operating Temperature (Device Grade 3) –40 125 °C
Symbol Parameter Min. Max. Unit
V
CC
Supply Voltage 2.5 5.5 V
T
A
Ambient Operating Temperature (Device Grade 6) –40 85 °C
Ambient Operating Temperature (Device Grade 3) –40 125 °C
Symbol
Parameter Min.
1
Max.
1
Unit
V
CC
Supply Voltage 1.8 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Symbol
Parameter Min.
1
Max.
1
Unit
V
CC
Supply Voltage 1.65 5.5 V
T
A
Ambient Operating Temperature –40 85 °C
Symbol Parameter Min. Typ. Max. Unit
C
L
Load Capacitance 30 pF
Input Rise and Fall Times 50 ns
Input Pulse Voltages
0.2V
CC
to 0.8V
CC
V
Input and Output Timing Reference Voltages
0.3V
CC
to 0.7V
CC
V