Datasheet
M95640-W M95640-R M95640-DF Instructions
Doc ID 16877 Rev 17 27/49
6.9  Read Lock Status (available only in M95640-D devices)
The Read Lock Status instruction (see Ta ble 4) is used to check whether the Identification 
Page is locked or not in Read-only mode. The Read Lock Status sequence is defined with 
the Chip Select (S
) first driven low. The bits of the instruction byte and address bytes are 
then shifted in on Serial Data Input (D). Address bit A10 must be 1, all other address bits are 
Don't Care. The Lock bit is the LSB (least significant bit) of the byte read on Serial Data 
Output (Q). It is at “1” when the lock is active and at “0” when the lock is not active. If Chip 
Select (S
) continues to be driven low, the same data byte is shifted out. The read cycle is 
terminated by driving Chip Select (S
) high.
The instruction sequence is shown in Figure 17.
Figure 17. Read Lock Status sequence
#
$
!I
3
1
                
     
  
  
(IGHIMPEDANCE
$ATA/UT
)NSTRUCTION BITADDRESS
-3"
-3"
$ATA/UT