Datasheet

DC and AC parameters M95512-W M95512-R M95512-DR M95512-DF
40/50 DocID11124 Rev 21
Table 21. AC characteristics (M95512-R and M95512-DF, device grade 6)
Test conditions: refer to Table 9 or Table 10 and Table 11
(1)(2)
Symbol Alt. Parameter
Min. Max. Min. Max.
Unit
Previous
(3)
products
Current
products
f
C
f
SCK
Clock frequency D.C. 2 D.C. 5 MHz
t
SLCH
t
CSS1
S active setup time 200 - 60 - ns
t
SHCH
t
CSS2
S not active setup time 200 - 60 - ns
t
SHSL
t
CS
S deselect time 200 - 90 - ns
t
CHSH
t
CSH
S active hold time 200 - 60 - ns
t
CHSL
S not active hold time 200 - 60 - ns
t
CH
(4)
t
CLH
Clock high time 200 - 80 - ns
t
CL
(4)
t
CLL
Clock low time 200 - 80 - ns
t
CLCH
(5)
t
RC
Clock rise time - 1 - 2 µs
t
CHCL
(5)
t
FC
Clock fall time - 1 - 2 µs
t
DVCH
t
DSU
Data in setup time 40 - 20 - ns
t
CHDX
t
DH
Data in hold time 50 - 20 - ns
t
HHCH
Clock low hold time after HOLD not active 140 - 60 - ns
t
HLCH
Clock low hold time after HOLD active 90 - 60 - ns
t
CLHL
Clock low setup time before HOLD active 0 - 0 - ns
t
CLHH
Clock low setup time before HOLD not active 0 - 0 - ns
t
SHQZ
(5)
t
DIS
Output disable time - 250 - 80 ns
t
CLQV
t
V
Clock low to output valid - 150 - 80 ns
t
CLQX
t
HO
Output hold time 0 - 0 - ns
t
QLQH
(5)
t
RO
Output rise time - 100 - 80 ns
t
QHQL
(5)
t
FO
Output fall time - 100 - 80 ns
t
HHQV
t
LZ
HOLD high to output valid - 100 - 80 ns
t
HLQZ
(5)
t
HZ
HOLD low to output High-Z - 250 - 80 ns
t
W
t
WC
Write time - 5 - 5 ms
1. The test flow guarantees the AC parameter values defined in this table (when V
CC
= 1.8 V or V
CC
= 1.7 V)
and the parameter values defined in AC characteristics tables for M95512-W (when V
CC
> 2.5 V).
2. If the application uses the device at 2.5 V V
CC
5.5 V and –40 °C T
A
+85 °C, please refer to Table 20
instead of the above table.
3. Not for new designs (previous products are identified by process letters AB)
4. t
CH
+ t
CL
must never be less than the shortest possible clock period, 1 / f
C
(max)
5. Characterized only, not tested in production.