Datasheet

DC and AC parameters M95512-W M95512-R M95512-DR M95512-DF
38/50 DocID11124 Rev 21
Table 19. AC characteristics (previous M95512-W products, device grade 6)
Test conditions: refer to Table 8 and Table 11
(1)
1. Not for new designs (previous products are identified by process letters AB).
Symbol Alt. Parameter Min. Max. Unit
f
C
f
SCK
Clock frequency D.C. 5 MHz
t
SLCH
t
CSS1
S active setup time 90 - ns
t
SHCH
t
CSS2
S not active setup time 90 - ns
t
SHSL
t
CS
S deselect time 100 - ns
t
CHSH
t
CSH
S active hold time 90 - ns
t
CHSL
S not active hold time 90 - ns
t
CH
(2)
2. t
CH
+ t
CL
must never be less than the shortest possible clock period, 1 / f
C
(max).
t
CLH
Clock high time 90 - ns
t
CL
(2)
t
CLL
Clock low time 90 - ns
t
CLCH
(3)
3. Characterized only, not tested in production.
t
RC
Clock rise time - 1 µs
t
CHCL
(3)
t
FC
Clock fall time - 1 µs
t
DVCH
t
DSU
Data in setup time 20 - ns
t
CHDX
t
DH
Data in hold time 30 - ns
t
HHCH
Clock low hold time after HOLD not active 70 - ns
t
HLCH
Clock low hold time after HOLD active 40 - ns
t
CLHL
Clock low setup time before HOLD active 0 - ns
t
CLHH
Clock low setup time before HOLD not active 0 - ns
t
SHQZ
(3)
t
DIS
Output disable time - 100 ns
t
CLQV
t
V
Clock low to output valid - 60 ns
t
CLQX
t
HO
Output hold time 0 - ns
t
QLQH
(3)
t
RO
Output rise time - 50 ns
t
QHQL
(3)
t
FO
Output fall time - 50 ns
t
HHQV
t
LZ
HOLD high to output valid - 50 ns
t
HLQZ
(3)
t
HZ
HOLD low to output High-Z - 100 ns
t
W
t
WC
Write time - 5 ms