Datasheet

DC and AC parameters M95512-W M95512-R M95512-DR M95512-DF
36/50 DocID11124 Rev 21
Table 17. DC characteristics (M95512-R and M95512-DR products, device grade 6)
Symbol Parameter
Test conditions in addition to those defined
in Table 9
(1)
Min Max Unit
I
LI
Input leakage current V
IN
= V
SS
or
V
CC
2µA
I
LO
Output leakage current S = V
CC
, voltage applied on Q = V
SS
or
V
CC
2µA
I
CC
Supply current (Read)
C = 0.1 V
CC
/0.9 V
CC
at max clock
frequency
(2)
,
V
CC
= 1.8 V, Q = open
-2.5mA
I
CC0
(3)
Supply current (Write) During t
W
, S = V
CC
, 1.8 V < V
CC
< 2.5 V - 1.5 mA
I
CC1
Supply current (Standby
Power mode)
S
= V
CC
, V
CC
= 1.8 V, V
IN
= V
SS
or
V
CC
-1
(4)
µA
V
IL
Input low voltage –0.45 0.3 V
CC
V
V
IH
Input high voltage 0.7 V
CC
V
CC
+1 V
V
OL
Output low voltage I
OL
= 0.15 mA, V
CC
= 1.8 V - 0.3 V
V
OH
Output high voltage I
OH
= –0.1 mA, V
CC
= 1.8 V 0.8 V
CC
-V
1. If the application uses the M95512-R or M95512-DR with 2.5 V V
CC
< 5.5 V and -40 °C < TA < +85 °C,
please refer to Table 16 and Table 15 instead of the above table.
2. Max clock frequency is 5 MHz (was 2 MHz for previous products identified with process letters AB).
3. Characterized only, not tested in production.
4. 1 µA for devices from date code 301 (year 2013, W01), 3 µA for previous devices.