Datasheet

DocID11124 Rev 21 35/50
M95512-W M95512-R M95512-DR M95512-DF DC and AC parameters
Table 16. DC characteristics (M95512-W products, device grade 6)
Symbol Parameter
Test conditions in addition to those defined in
Table 8
(1)
Min. Max. Unit
I
LI
Input leakage
current
V
IN
= V
SS
or
V
CC
2µA
I
LO
Output leakage
current
S
= V
CC
, voltage applied on Q = V
SS
or
V
CC
2µA
I
CC
Supply current
(Read)
C = 0.1 V
CC
/0.9V
CC
at 10 MHz, V
CC
= 2.5 V,
Q = open
-4mA
C = 0.1 V
CC
/0.9V
CC
at 16 MHz, V
CC
= 5 V, Q = open - 8 mA
I
CC0
(2)
Supply current
(Write)
During t
W
, S = V
CC
, 2.5 V < V
CC
< 5.5 V - 2 mA
I
CC1
Supply current
(Standby Power
mode)
S = V
CC
, V
CC
= 2.5 V, V
IN
= V
SS
or
V
CC
-2
(3)
µA
S = V
CC
, V
CC
= 5.5 V, V
IN
= V
SS
or
V
CC
-3
(4)
µA
V
IL
Input low voltage –0.45 0.3 V
CC
V
V
IH
Input high voltage 0.7 V
CC
V
CC
+1 V
V
OL
Output low voltage
V
CC
= 2.5 V and I
OL
= 1.5 mA or
V
CC
= 5 V and I
OL
= 2 mA
-0.4V
V
OH
Output high
voltage
V
CC
= 2.5 V and I
OH
= –0.4 mA or
V
CC
= 5 V and I
OH
= –2 mA
0.8 V
CC
-V
1. For devices identified by process letter KB.
2. Characterized only, not tested in production.
3. 2 µA for devices from date code 301 (year 2013, W01), 5 µA for previous devices.