Datasheet

DC and AC parameters M95512-W M95512-R M95512-DR M95512-DF
34/50 DocID11124 Rev 21
Table 15. DC characteristics (previous M95512-W products, device grade 6)
Symbol Parameter
Test conditions in addition to those
defined in Table 8
(1)
1. Not for new designs (previous products identified by process letters AB operate with a clock
frequency of 5 MHz max).
Min. Max. Unit
I
LI
Input leakage
current
V
IN
= V
SS
or
V
CC
2µA
I
LO
Output leakage
current
S
= V
CC
, V
OUT
= V
SS
or
V
CC
2µA
I
CC
Supply current
(Read)
C = 0.1 V
CC
/0.9 V
CC
at 5 MHz,
V
CC
= 2.5 V, Q = open
-3
mA
C = 0.1 V
CC
/0.9 V
CC
at 5 MHz,
V
CC
= 5 V, Q = open
-5
I
CC0
(2)
2. Characterized only, not tested in production.
Supply current
(Write)
During t
W
, S = V
CC
,
2.5 V < V
CC
< 5.5 V
-6mA
I
CC1
Supply current
(Standby Power
mode)
S
= V
CC
, 2.5 V <V
CC
< 5.5 V
V
IN
= V
SS
or
V
CC
-5µA
V
IL
Input low voltage –0.45 0.3 V
CC
V
V
IH
Input high voltage 0.7 V
CC
V
CC
+1 V
V
OL
Output low voltage
V
CC
= 2.5 V and I
OL
= 1.5 mA or
V
CC
= 5 V and I
OL
= 2 mA
-0.4V
V
OH
Output high voltage
V
CC
= 2.5 V and I
OH
= –0.4 mA or
V
CC
= 5 V and I
OH
= –2 mA
0.8 V
CC
-V