Datasheet
DC and AC parameters M95512-W M95512-R M95512-DR M95512-DF
32/50 DocID11124 Rev 21
9 DC and AC parameters
This section summarizes the operating conditions and the DC/AC characteristics of the
device.
Figure 19. AC measurement I/O waveform
Table 8. Operating conditions (M95512-W, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 9. Operating conditions (M95512-R and M95512-DR, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 10. Operating conditions (M95512-DF, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 11. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 30 pF
Input rise and fall times - ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
AI00825C
0.8 V
CC
0.2 V
CC
0.7 V
CC
0.3 V
CC
Input and output
timing reference levels
Input voltage levels