Datasheet

DC and AC parameters M95320-W M95320-R M95320-DF
36/46 Doc ID 5711 Rev 15
Table 18. DC characteristics (M95320-DF, device grade 6)
Symbol Parameter Test conditions
(1)
Min. Max. Unit
I
LI
Input leakage
current
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output leakage
current
S
= V
CC
, voltage applied on Q = V
SS
or V
CC
± 2 µA
I
CC
Supply current
(Read)
V
CC
= 1.7 V, max clock frequency (f
C),
C = 0.1 V
CC
/0.9 V
CC
, Q = open
2
mA
V
CC
= 1.7 V, f
C
= 5 MHz,
C = 0.1 V
CC
/0.9 V
CC
, Q = open
2
I
CC0
(2)
Supply current
(Write)
V
CC
= 1.7 V, during t
W
, S = V
CC
5mA
I
CC1
Supply current
(Standby)
V
CC
= 1.7 V, S = V
CC
, V
IN
= V
SS
or
V
CC
A
V
IL
Input low voltage 1.7 V V
CC
< 2.5 V –0.45 0.25 V
CC
V
V
IH
Input high voltage 1.7 V V
CC
< 2.5 V 0.75 V
CC
V
CC
+1 V
V
OL
Output low voltage I
OL
= 0.15 mA, V
CC
= 1.7 V 0.3 V
V
OH
Output high voltage I
OH
= –0.1 mA, V
CC
= 1.7 V 0.8 V
CC
V
V
RES
(2)
Internal reset
threshold voltage
1.0 1.65 V
1. If the application uses the M95320-DF devices at 2.5 V V
CC
5.5 V and –40 °C T
A
+85 °C, please refer to Table 16:
DC characteristics (M95320-W, device grade 6), rather than to the above table.
2. Characterized only, not tested in production.