Datasheet

M95320-W M95320-R M95320-DF DC and AC parameters
Doc ID 5711 Rev 15 35/46
Table 17. DC characteristics (M95320-R, device grade 6)
Symbol Parameter Test conditions
(1)
Min. Max. Unit
I
LI
Input leakage
current
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output leakage
current
S
= V
CC
, voltage applied on Q = V
SS
or V
CC
± 2 µA
I
CC
Supply current
(Read)
V
CC
= 1.8 V, max clock frequency (f
C
),
C = 0.1V
CC
/0.9V
CC
, Q = open
2
mA
V
CC
= 1.8 V, f
C
= 5 MHz,
C = 0.1V
CC
/0.9V
CC
, Q = open
2
(2)
I
CC0
(3)
Supply current
(Write)
V
CC
= 1.8 V, during t
W
, S = V
CC
5mA
I
CC1
Supply current
(Standby)
V
CC
= 1.8 V, S = V
CC
, V
IN
= V
SS
or
V
CC
A
V
IL
Input low voltage 1.8 V V
CC
< 2.5 V –0.45 0.25 V
CC
V
V
IH
Input high voltage 1.8 V V
CC
< 2.5 V 0.75 V
CC
V
CC
+1 V
V
OL
Output low voltage I
OL
= 0.15 mA, V
CC
= 1.8 V 0.3 V
V
OH
Output high voltage I
OH
= –0.1 mA, V
CC
= 1.8 V 0.8 V
CC
V
V
RES
(3)
Internal reset
threshold voltage
1.0
(4)
1.65
(5)
V
1. If the application uses the M95320-R device with 2.5 V < V
CC
< 5.5 V and -40 °C < TA < +85 °C, please refer to Table 16:
DC characteristics (M95320-W, device grade 6), rather than to the above table.
2. For the device identified by process letter K.
3. Characterized only, not tested in production.
4. 0.7 V with the device identified by process letter K.