Datasheet
DC and AC parameters M95320-W M95320-R M95320-DF
32/46 Doc ID 5711 Rev 15
9 DC and AC parameters
This section summarizes the operating conditions and the DC/AC characteristics of the
device.
Figure 18. AC measurement I/O waveform
Table 9. Operating conditions (M95320-W, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 10. Operating conditions (M95320-R, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 11. Operating conditions (M95320-DF, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 12. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 30 pF
Input rise and fall times 25 ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
!)#
6
##
6
##
6
##
6
##
)NPUTANDOUTPUT
TIMINGREFERENCELEVELS
)NPUTVOLTAGELEVELS