Datasheet
DC and AC parameters M95256-W M95256-R M95256-DR M95256-DF
32/52 DocID12276 Rev 20
9 DC and AC parameters
This section summarizes the operating conditions and the DC/AC characteristics of the
device.
Figure 19. AC measurement I/O waveform
Table 9. Operating conditions (M95256-W, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 10. Operating conditions (M95256-R and M95256-DR, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 11. Operating conditions (M95256-DF, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 12. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 30 or 100
(1)
1. 100 pF when the clock frequency f
C
is less than 10 MHz, 30 pF when the clock frequency f
C
is
equal to or greater than 10 MHz.
pF
Input rise and fall times - 25 ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
AI00825C
0.8 V
CC
0.2 V
CC
0.7 V
CC
0.3 V
CC
Input and output
timing reference levels
Input voltage levels