Datasheet

DocID12276 Rev 20 31/52
M95256-W M95256-R M95256-DR M95256-DF Maximum rating
8 Maximum rating
Stressing the device outside the ratings listed in Table 8 may cause permanent damage to
the device. These are stress ratings only, and operation of the device at these, or any other
conditions outside those indicated in the operating sections of this specification, is not
implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Table 8. Absolute maximum ratings
Symbol Parameter Min. Max. Unit
Ambient operating temperature –40 130 °C
T
STG
Storage temperature –65 150 °C
T
LEAD
Lead temperature during soldering See note
(1)
1. Compliant with JEDEC Std J-STD-020D (for small body, Sn-Pb or Pb-free assembly), the ST
ECOPACK® 7191395 specification, and the European directive on Restrictions of Hazardous
Substances (RoHS) 2011/65/EU.
°C
V
O
Output voltage –0.50 V
CC
+0.6 V
V
I
Input voltage –0.50 6.5 V
V
CC
Supply voltage –0.50 6.5 V
I
OL
DC output current (Q = 0) - 5 mA
I
OH
DC output current (Q = 1) - 5 mA
V
ESD
Electrostatic discharge voltage (human body model)
(2)
2. Positive and negative pulses applied on different combinations of pin connections, according to
AEC-Q100-002 (compliant with JEDEC Std JESD22-A114, C1=100 pF, R1=1500 Ω,
R2=500 Ω).
- 4000
(3)
3. V
ESD
is 3000 V (max) for the M95256 identified by process letters KA.
V