Datasheet
Instructions M95256-W M95256-R M95256-DR M95256-DF
28/52 DocID12276 Rev 20
6.9 Read Lock Status (available only in M95256-D devices)
The Read Lock Status instruction (see Table 4) is used to check whether the Identification
Page is locked or not in Read-only mode. The Read Lock Status sequence is defined with
the Chip Select (
S) first driven low. The bits of the instruction byte and address bytes are
then shifted in on Serial Data Input (D). Address bit A10 must be 1, all other address bits are
Don't Care. The Lock bit is the LSB (least significant bit) of the byte read on Serial Data
Output (Q). It is at “1” when the lock is active and at “0” when the lock is not active. If Chip
Select (
S) continues to be driven low, the same data byte is shifted out. The read cycle is
terminated by driving Chip Select (
S) high.
The instruction sequence is shown in figure below.
Figure 17. Read Lock Status sequence
C
D
Ai15966
S
Q
15
21 3 4 5 6 7 8 9 10 20 21 22 23 24 25 26 27
14 13 3 2 1 0
28 29 30
76543 1 7
0
High impedance
Data Out 1
Instruction 16-bit address
0
MSB
MSB
2
31
Data Out 2