Datasheet
DC and AC parameters M95128-W M95128-R M95128-DF
34/49 Doc ID 5798 Rev 16
Table 16. DC characteristics (M95128-W, device grade 6)
Symbol Parameter
Test conditions in addition to those
defined in Ta ble 9 and Table 12
Min. Max. Unit
I
LI
Input leakage
current
V
IN
= V
SS
or
V
CC
± 2 µA
I
LO
Output leakage
current
S
= V
CC
, V
OUT
= V
SS
or
V
CC
± 2 µA
I
CC
Supply current
(Read)
V
CC
= 2.5 V, C = 0.1 V
CC
/0.9 V
CC
at 5 MHz, Q = open
3
(1)
1. For previous products identified with process letter A.
mA
V
CC
= 2.5 V, C = 0.1 V
CC
/0.9 V
CC
at 10 MHz, Q = open
2
(2)
V
CC
= 5.5 V, C = 0.1 V
CC
/0.9 V
CC
at 5 MHz, Q = open
5
(1)
V
CC
= 5.5 V, C = 0.1 V
CC
/0.9 V
CC
at 20 MHz, Q = open
5
(2)
2. For the M95128 devices identified by process letter K.
I
CC0
(3)
3. Characterized only, not tested in production.
Supply current
(Write)
During t
W
, S = V
CC
,
2.5 V < V
CC
< 5.5 V
mA
I
CC1
Supply current
(Standby)
S = V
CC
, V
CC
= 5.5 V,
V
IN
= V
SS
or
V
CC
,
3
(4)
4. 5 µA for previous M95128 devices identified by process letter A.
µA
S
= V
CC
, V
CC
= 2.5 V,
V
IN
= V
SS
or
V
CC
,
2
(4)
V
IL
Input low voltage –0.45 0.3 V
CC
V
V
IH
Input high voltage 0.7 V
CC
V
CC
+1 V
V
OL
Output low voltage
V
CC
= 2.5 V and I
OL
= 1.5 mA or
V
CC
= 5 V and I
OL
= 2 mA
0.4 V
V
OH
Output high voltage
V
CC
= 2.5 V and I
OH
= –0.4 mA or
V
CC
= 5 V and I
OH
= –2 mA
0.8 V
CC
V