Datasheet
DocID6512 Rev 12 31/45
M950x0-W M950x0-R M950x0-DF DC and AC parameters
44
9 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Figure 18. AC test measurement I/O waveform
(1)
1. Output Hi-Z is defined as the point where data out is no longer driven.
Table 9. Operating conditions (M950x0-W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Table 10. Operating conditions (M950x0-R)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.8 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 11. Operating conditions (M95040-DF, device grade 6)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 1.7 5.5 V
T
A
Ambient operating temperature –40 85 °C
Table 12. AC test measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 30 pF
Input rise and fall times - 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
V
Input and output timing reference voltages 0.3V
CC
to 0.7V
CC
V
ai00825b
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
Input and Output
Timing Reference Levels
Input Levels