Datasheet

DC and AC parameters M93S46-W M93S56-W M93S66-W
26/37 DocID5124 Rev 6
8 DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Figure 8. AC test measurement I/O waveform
Table 5. Operating conditions (M93Sx6-W)
Symbol Parameter Min. Max. Unit
V
CC
Supply voltage 2.5 5.5 V
T
A
Ambient operating temperature (device grade 6) –40 85 °C
Table 6.
AC test measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 100 pF
Input rise and fall times - 50 ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
V
Input and output timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
AI00825B
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
Input and Output
Timing Reference Levels
Input Levels