DC and AC parameters M93C86-x M93C76-R M93C66-x M93C56-x M93C46-x
22/33 DocID4997 Rev 15
Table 14. DC characteristics (M93Cx6-W, device grade 6)
Symbol Parameter
Test condition (in addition to
the conditions defined in
Table 8 and Table 12)
Min. Max. Unit
I
LI
Input leakage current 0V V
IN
V
CC
-±2.5 µA
I
LO
Output leakage current 0V V
OUT
V
CC
, Q in Hi-Z - ±2.5 µA
I
CC
Operating supply current
V
CC
= 5 V, S = V
IH
, f = 2 MHz,
Q = open
-2 mA
V
CC
= 2.5 V, S = V
IH
, f = 2 MHz,
Q = open
-1 mA
I
CC1
Standby supply current
V
CC
= 2.5 V, S = V
SS
, C = V
SS
,
ORG = V
SS
or V
CC
,
pin7 = V
CC
, V
SS
or Hi-Z
-2
(1)
1. 5 µA for previous devices identified with the process letter G.
µA
V
CC
= 5.5 V, S = V
SS
, C = V
SS
,
ORG = V
SS
or V
CC
,
pin7 = VCC, V
SS
or Hi-Z
-3
(2)
2. Tested only for current devices identified with the process letter K.
µA
V
IL
Input low voltage (D, C, S) - –0.45 0.2 V
CC
V
V
IH
Input high voltage (D, C, S) - 0.7 V
CC
V
CC
+ 1 V
V
OL
Output low voltage (Q)
V
CC
= 5 V, I
OL
= 2.1 mA - 0.4 V
V
CC
= 2.5 V, I
OL
= 100 µA - 0.2 V
V
OH
Output high voltage (Q)
V
CC
= 5 V, I
OH
= –400 µA 0.8 V
CC
- V
V
CC
= 2.5 V, I
OH
= –100 µA V
CC
–0.2 - V
Table 15. DC characteristics (M93Cx6-R)
Symbol Parameter Test condition Min. Max.
Unit
I
LI
Input leakage current 0V V
IN
V
CC
-±2.5 µA
I
LO
Output leakage current 0V V
OUT
V
CC
, Q in Hi-Z - ±2.5 µA
I
CC
Operating supply current
V
CC
= 5 V, S = V
IH
, f = 2 MHz,
Q = open
-2 mA
V
CC
= 1.8 V, S = V
IH
, f = 1 MHz,
Q = open
-1 mA
I
CC1
Standby supply current
V
CC
= 1.8 V, S = V
SS
, C = V
SS
,
ORG = V
SS
or V
CC
,
pin7 = V
CC
, V
SS
or Hi-Z
-1
(1)
1. 2 µA for previous devices identified with process letter G.
µA
V
IL
Input low voltage (D, C, S) - –0.45 0.2 V
CC
V
V
IH
Input high voltage (D, C, S) - 0.8 V
CC
V
CC
+ 1 V
V
OL
Output low voltage (Q) V
CC
= 1.8 V, I
OL
= 100 µA - 0.2 V
V
OH
Output high voltage (Q) V
CC
= 1.8 V, I
OH
= –100 µA V
CC
–0.2 - V