Table 12. AC measurement conditions
Symbol Parameter Min. Max. Unit
C
L
Load capacitance 100 pF
- Input rise and fall times - 50 ns
- Input voltage levels 0.2 V
CC
to 0.8 V
CC
V
- Input timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
- Output timing reference voltages 0.3 V
CC
to 0.7 V
CC
V
Table 13. Input and output capacitance
Symbol Parameter Test condition
(1)
1. Sampled only, not 100% tested, at T
A
= 25 °C and a frequency of 1 MHz.
Min Max Unit
C
OUT
Output capacitance V
OUT
= 0V - 8 pF
C
IN
Input capacitance V
IN
= 0V - 6 pF
MS19788V3
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
Input and output