Datasheet
15/31
M93C86, M93C76, M93C66, M93C56, M93C46
Table 12. AC Measurement Conditions (M93Cx6)
Note: 1. Output Hi-Z is defined as the point where data out is no longer driven.
Table 13. AC Measurement Conditions (M93Cx6-W and M93Cx6-R)
Note: 1. Output Hi-Z is defined as the point where data out is no longer driven.
Figure 8. AC Testing Input Output Waveforms
Table 14. Capacitance
Note: Sampled only, not 100% tested, at T
A
=25°C and a frequency of 1MHz.
Symbol Parameter Min. Max. Unit
C
L
Load Capacitance 100 pF
Input Rise and Fall Times 50 ns
Input Pulse Voltages 0.4 V to 2.4 V V
Input Timing Reference Voltages 1.0 V and 2.0 V V
Output Timing Reference Voltages 0.8 V and 2.0 V V
Symbol Parameter Min. Max. Unit
C
L
Load Capacitance 100 pF
Input Rise and Fall Times 50 ns
Input Pulse Voltages
0.2V
CC
to 0.8V
CC
V
Input Timing Reference Voltages
0.3V
CC
to 0.7V
CC
V
Output Timing Reference Voltages
0.3V
CC
to 0.7V
CC
V
Symbol Parameter Test Condition Min Max Unit
C
OUT
Output
Capacitance
V
OUT
= 0V
5pF
C
IN
Input
Capacitance
V
IN
= 0V
5pF
AI02553
2.4V
0.4V
2.0V
0.8V
2V
1V
INPUT OUTPUT
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
M93CXX-W & M93CXX-R
M93CXX