Datasheet

Absolute maximum ratings and operating conditions M74HC4852
4/15 Doc ID 8791 Rev 7
2 Absolute maximum ratings and operating conditions
Note: Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these conditions is not implied.
Table 4. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
Supply voltage -0.5 to +7 V
V
IN
Control input voltage
-0.5 to V
CC
+
0.5
V
V
I/O
Switch I/O voltage
-0.5 to V
CC
+
0.5
V
I
CK
Control input diode current ± 25 mA
I
IOK
I/O diode current ± 25 mA
I
CC
DC V
CC
or ground current ± 50 mA
P
D
Power dissipation SO-16 500
(1)
mW
T
stg
Storage temperature -65 to +150 °C
T
L
Lead temperature (10 sec.) 300 °C
ESD
(JESD22)
Human body model (HBM) 2000 V
Machine model (MM) 200 V
Charged device model (CDM) 1000 V
1. Power dissipation at 65 °C. Derating from 65 °C to 125 °C: SO package -7 mW/°C.
Table 5. Recommended operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 2 to 6 V
V
I/O
Input output voltage 0 to V
CC
V
V
I/O
Static or dynamic voltage across switch
(1)
0 to 1.2 V
V
IN
Control input voltage 0 to V
CC
V
T
op
Operating temperature
SO16 -55 to +125 °C
SO16 (automotive grade) -40 to +125 °C
t
r
, t
f
Input rise and fall time
(2)
(channel select or enable inputs only)
V
CC
= 2.0 V 0 to 1000 ns
V
CC
= 3.0.V 0 to 800
V
CC
= 3.3 V 0 to 700
V
CC
= 4.5 V 0 to 500
V
CC
= 6.0 V 0 to 400
1. For voltage drops across the switch greater than 1.2 V (switch on), excessive V
CC
current may be drawn; i.e., the current
out of the switch may contain both V
CC
and switch input components. The reliability of the device is unaffected unless the
maximum ratings are exceeded.
2. V
IN
from 30% to 70% V
CC
of channel selected or enable inputs.