Datasheet
DC and AC parameters M48Z58, M48Z58Y
14/24 Doc ID 2559 Rev 11
4 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Tabl e 6:
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Table 6. Operating and AC measurement conditions
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 9. AC measurement load circuit
Table 7. Capacitance
Parameter M48Z58 M48Z58Y Unit
Supply voltage (V
CC
) 4.75 to 5.5 4.5 to 5.5 V
Ambient operating temperature (T
A
) 0 to 70 0 to 70 °C
Load capacitance (C
L
) 100 100 pF
Input rise and fall times ≤ 5 ≤ 5ns
Input pulse voltages 0 to 3 0 to 3 V
Input and output timing ref. voltages 1.5 1.5 V
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V. Sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance - 10 pF
C
IO
(3)
3. Outputs deselected.
Input / output capacitance - 10 pF
AI01030
5V
OUT
C
L
= 100pF or 5pF
C
L
includes JIG capacitance
1.9kΩ
DEVICE
UNDER
TEST
1kΩ