Datasheet
M48Z35, M48Z35Y DC and AC parameters
Doc ID 2608 Rev 10 15/24
4 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Ta bl e 8:
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Table 8. Operating and AC measurement conditions
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 10. AC measurement load circuit
Table 9. Capacitance
Parameter M48Z35 M48Z35Y Unit
Supply voltage (V
CC
) 4.75 to 5.5 4.5 to 5.5 V
Ambient operating temperature (T
A
) 0 to 70 0 to 70 °C
Load capacitance (C
L
) 100 100 pF
Input rise and fall times ≤ 5 ≤ 5ns
Input pulse voltages 0 to 3 0 to 3 V
Input and output timing ref. voltages 1.5 1.5 V
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V. Sampled only, not 100% tested.
2. Outputs deselected.
Min Max Unit
C
IN
Input capacitance -10pF
C
IO
(3)
3. At 25 °C.
Input / output capacitance -10pF
AI03211
C
L
= 100pF or
5pF
C
L
includes JIG capacitance
645Ω
DEVICE
UNDER
TEST
1.75V