Datasheet

DocID012578 Rev 16 51/64
M41T82, M41T83 DC and AC parameters
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the dc and
ac characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Figure 26. Measurement AC I/O waveform
Table 19. Operating and AC measurement conditions
Parameter
(1)
1. Output Hi-Z is defined as the point where data is no longer driven.
M41T8x
Supply voltage (V
CC
) 2.38 V to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
) 50 pF
Input rise and fall times 5 ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
Input and output timing ref. voltages 0.3 V
CC
to 0.7 V
CC
Table 20. Capacitance
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 3.6 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz
Min Max Unit
C
IN
Input capacitance 7 pF
C
OUT
(3)
3. Outputs deselected
Output capacitance 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC