Datasheet

DC and AC parameters M41T81S
24/32 Doc ID 10773 Rev 7
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 7. Operating and AC measurement conditions
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 15. AC measurement I/O waveform
Table 8. Capacitance
Parameter M41T81S
Supply voltage (V
CC
) 2.7 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
) 100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz
Min Max Unit
C
IN
Input capacitance - 7 pF
C
OUT
(3)
3. Outputs deselected
Output capacitance - 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) - 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC