Datasheet
M41T81 DC and AC parameters
Doc ID 7529 Rev 10 21/29
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 14. AC measurement I/O waveform
Table 7. Operating and AC measurement conditions
Parameter M41T81
Supply voltage (V
CC
) 2.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85°C
Load capacitance (C
L
)100 pF
Input rise and fall times ≤ 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
Table 8. Capacitance
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance - 7 pF
C
OUT
(3)
3. Outputs deselected.
Output capacitance - 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) - 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC