Datasheet

M41T80 DC and AC parameters
Doc ID 9074 Rev 5 19/27
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Figure 12. AC measurement I/O waveform
Table 8. Operating and AC measurement conditions
(1)
1. Output Hi-Z is defined as the point where data is no longer driven.
Parameter M41T80
Supply voltage (V
CC
) 2.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
)100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
Table 9. Capacitance
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance 7 pF
C
OUT
(3)
3. Outputs deselected.
Output capacitance 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC