Datasheet
DocID10396 Rev 14 19/28
M41T60 DC and AC parameters
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 14. AC testing I/O waveform
Figure 15. Crystal isolation example
Note: Substrate pad should be tied to V
SS
.
Table 5. Operating and AC measurement conditions
Parameter M41T60
Supply voltage (V
CC
) 1.3 V to 4.4 V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
) 50 pF
Input rise and fall times ≤ 5 ns
Input pulse voltages 0.2 V
CC
to 0.8 V
CC
Input and output timing ref. voltages 0.3 V
CC
to 0.7 V
CC
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
AI09127
Crystal
XI
XO
GND
Local Grounding Plane
(Layer 2)