Datasheet
Table Of Contents
- 1 Description
- 2 Operation
- 3 Clock operation
- 4 Maximum ratings
- 5 DC and AC parameters
- Table 5. Operating and AC measurement conditions
- Figure 14. AC testing input/output waveform
- Table 6. Capacitance
- Table 7. DC characteristics
- Table 8. Crystal electrical characteristics
- Figure 15. Power down/up mode AC waveforms
- Table 9. Power down/up AC characteristics
- Table 10. Power down/up trip points DC characteristics
- 6 Package mechanical data
- Figure 16. SO8 - 8-lead plastic small outline package outline
- Table 11. SO8 - 8-lead plastic small outline (150 mils body width) package mechanical data
- Figure 17. SOH28 - 28-lead plastic small outline, battery SNAPHAT® package outline
- Table 12. SOH28 - 28-lead plastic small outline, battery SNAPHAT® package mechanical data
- Figure 18. SH - 4-pin SNAPHAT® housing for 48 mAh battery & crystal package outline
- Table 13. SH - 4-pin SNAPHAT® housing for 48 mAh battery & crystal, package mechanical data
- Figure 19. SH - 4-pin SNAPHAT® housing for 120 mAh battery & crystal, package outline
- Table 14. SH - 4-pin SNAPHAT® housing for 120 mAh battery & crystal, package mech. data
- 7 Part numbering
- 8 Environmental information
- 9 Revision history

M41T11 DC and AC parameters
Doc ID 6103 Rev 10 21/30
Figure 15. Power down/up mode AC waveforms
Table 9. Power down/up AC characteristics
Symbol Parameter
(1)(2)
1. Valid for ambient operating temperature: T
A
= –40 to 85°C; V
CC
= 2.0 to 5.5 V (except where noted).
2. V
CC
fall time should not exceed 5 mV/µs.
Min Max Unit
t
PD
SCL and SDA at V
IH
before power down 0 ns
t
REC
SCL and SDA at V
IH
after power up 10 µs
Table 10. Power down/up trip points DC characteristics
Symbol Parameter
(1)(2)
1. Valid for ambient operating temperature: T
A
= –40 to 85°C; V
CC
= 2.0 to 5.5 V (except where noted).
2. All voltages referenced to V
SS
.
Min Typ Max
(3)
3. In 3.3 V application, if initial battery voltage is ≥ 3.4 V, it may be necessary to reduce battery voltage (i.e.,
through wave soldering the battery) in order to avoid inadvertent switchover/deselection for V
CC
– 10%
operation.
Unit
V
SO
(4)
4. Switchover and deselect point.
Battery backup switchover voltage V
BAT
– 0.80 V
BAT
– 0.50 V
BAT
– 0.30 V
AI00596
V
CC
tREC
tPD
V
SO
SDA
SCL
DON'T CARE