Datasheet

Table Of Contents
M41T11 DC and AC parameters
Doc ID 6103 Rev 10 19/30
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Ta bl e 5 :
Operating and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Figure 14. AC testing input/output waveform
Table 5. Operating and AC measurement conditions
(1)
1. Output Hi-Z is defined as the point where data is no longer driven.
Parameter M41T11 Unit
Supply voltage (V
CC
) 2.0 to 5.5
(2)
2. Supply voltage for SOH28 is 3.3 V to 5.5 V.
V
Ambient operating temperature (T
A
) –40 to 85 °C
Load capacitance (C
L
) 100 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2V
CC
to 0.8V
CC
V
Input and output timing ref. voltages 0.3V
CC
to 0.7V
CC
V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC