Datasheet

M41ST87Y, M41ST87W DC and AC parameters
Doc ID 9497 Rev 10 43/54
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 15. DC and AC measurement conditions
Note: Output high Z is defined as the point where data is no longer driven.
Figure 27. AC testing input/output waveforms
Table 16. Capacitance
Parameter M41ST87Y M41ST87W
V
CC
supply voltage 4.5 to 5.5 V 2.7 to 3.6 V
Ambient operating temperature –40 to 85 °C –40 to 85 °C
Load capacitance (C
L
) 100 pF 50 pF
Input rise and fall times 50 ns 50 ns
Input pulse voltages 0.2 to 0.8V
CC
0.2 to 0.8V
CC
Input and output timing ref. voltages 0.3 to 0.7V
CC
0.3 to 0.7V
CC
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V. Sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance 7 pF
C
OUT
(3)
3. Outputs are deselected.
Output capacitance 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC