M41ST85W DC and AC parameters
Doc ID 7531 Rev 11 33/43
Figure 20. Power down/up mode AC waveforms
Table 13. Power down/up AC characteristics
Symbol Parameter
(1)
1. Valid for ambient operating temperature: T
A
= –40 to 85°C; V
CC
= 2.7 to 3.6 V (except where otherwise noted).
Min Typ Max Unit
t
F
(2)
2. V
PFD
(max) to V
PFD
(min) fall time of less than t
F
may result in deselection/write protection not occurring until
200 µs after V
CC
passes V
PFD
(min).
V
PFD
(max) to V
PFD
(min) V
CC
fall time 300 µs
t
FB
(3)
3. V
PFD
(min) to V
SS
fall time of less than t
FB
may cause corruption of RAM data.
V
PFD
(min) to V
SS
V
CC
fall time 10 µs
t
PD
EX at V
IH
before power down 0 µs
t
PFD
PFI to PFO propagation delay 15 25 µs
t
R
V
PFD
(min) to V
PFD
(max) V
CC
rise time 10 µs
t
RB
V
SS
to V
PFD
(min) V
CC
rise time 1 µs
t
rec
(4)
4. Programmable (see Table 6 on page 28)
Power-up deselect time 40 200 ms
AI03661
V
CC
INPUTS
(PER CONTROL INPUT)
OUTPUTS
DON'T CARE
HIGH-Z
tF
tFB
tR
tPD
tRB
tDR
VALID VALID
(PER CONTROL INPUT)
RECOGNIZEDRECOGNIZED
V
PFD
(max)
V
PFD
(min)
V
SO
trec
RST
E
CON
PFO