DC and AC parameters M41ST85W
30/43 Doc ID 7531 Rev 11
5 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Table 9. DC and AC measurement conditions
Note: Output High Z is defined as the point where data is no longer driven.
Figure 18. AC testing input/output waveforms
Table 10. Capacitance
Parameter M41ST85W
V
CC
supply voltage 2.7 to 3.6 V
Ambient operating temperature –40 to 85°C
Load capacitance (C
L
)50 pF
Input rise and fall times 50 ns
Input pulse voltages 0.2 to 0.8V
CC
Input and output timing ref. voltages 0.3 to 0.7V
CC
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V. Sampled only, not 100% tested.
2. At 25°C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance 7 pF
C
OUT
(3)
3. Outputs are deselected.
Output capacitance 10 pF
t
LP
Low-pass filter input time constant (SDA and SCL) 50 ns
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC