Datasheet
DocID007528 Rev 4 15/20
M40SZ100W DC and AC parameters
20
4 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in Table 5:
DC and AC measurement conditions. Designers should check that the operating conditions
in their projects match the measurement conditions when using the quoted parameters.
Table 5. DC and AC measurement conditions
Figure 9. AC testing load circuit
Figure 10. AC testing input/output waveforms
Table 6. Capacitance
Parameter Value
V
CC
supply voltage 2.7 to 3.6 V
Ambient operating temperature –40 to 85 °C
Load capacitance (C
L
) 50 pF
Input rise and fall times 5 ns
Input pulse voltages 0.2 to 0.8V
CC
Input and output timing ref. voltages 0.3 to 0.7V
CC
Symbol Parameter
(1)(2)
1. Sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
IN
Input capacitance - 7 pF
C
OUT
(3)
3. Outputs deselected.
Output capacitance - 10 pF
AI02393
C
L
= 50pF
C
L
includes JIG capacitance
333
DEVICE
UNDER
TEST
1.73V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC