Datasheet
Maximum rating M24M02-DR
22/36 DocID18204 Rev 6
7 Maximum rating
Stressing the device outside the ratings listed in Table 5 may cause permanent damage to
the device. These are stress ratings only, and oper
ation of the device at these, or any other
conditions outside those indicated in the operating sections of this specification, is not
implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Table 5. Absolute maximum ratings
Symbol Parameter Min. Max. Unit
Ambient operating temperature –40 130 °C
T
STG
Storage temperature –65 150 °C
T
LEAD
Lead temperature during soldering see note
(1)
1. Compliant with JEDEC Std J-STD-020D (for small body, Sn-Pb or Pb-free assembly), the ST
ECOPACK® 7191395 specification, and the European directive on Restrictions of Hazardous
Substances (RoHS) 2011/65/EU.
°C
I
OL
DC output current (SDA = 0) - 5 mA
V
IO
Input or output range –0.50 6.5 V
V
CC
Supply voltage –0.50 6.5 V
V
ESD
Electrostatic pulse (Human Body model)
(2)
2. Positive and negative pulses applied on different combinations of pin connections, according to
AEC-Q100-002 (compliant with JEDEC Std JESD22-A114, C1=100 pF, R1=1500 Ω).
-3000V